Industrial Cables-Australian Standard (LV)
PVC Insulated, Round Cables, 450/750V
Application
These cables are used for control circuits unenclosed, enclosed in conduit, buried direct or in underground ducts for commercial, industrial, mining and electricity authority systems where not subject to mechanical damage.
Standard
- AS/NZS 5000.2
- AS 1125
- AS 3808
Cable Construction
CONDUCTOR | Plain annealed copper. Maximum operating temperature: 90°C |
INSULATION | PVC V90. |
INSULATION COLOUR: | 2C: Red, Black 3C: Red, White & Blue 4C: Red, White, Blue, & Black 7-37C: White (Numbered) |
SHEATH: | Polyvinylchloride compound PVC 5V90 |
SHEATH COLOUR: | Black, other colors are available upon request |
Technical Characteristics
CONDUCTOR NOMINAL AREA MM2 |
CURRENT RATINGS | ELECTRICAL CHARACTERISTICS | |||||
UNENCLOSED IN AIR A |
BURIED DIRECT A |
BURIED IN DUCTS A | MAXIMUM DC RESISTANCE @20°C OHM/KM |
MAXIMUM AC RESISTANCE @75°C OHM/KM |
REACTANCE OHM/KM | SINGLE PHASE VOLTAGE DROP @75°C |
|
2 cores | |||||||
1.5 | 21 | 31 | 24 | 13.6 | 16.5 | 0.111 | 33.0 |
2.5 | 30 | 44 | 34 | 7.41 | 9.01 | 0.102 | 18.0 |
3 cores | |||||||
1.5 | 17 | 26 | 21 | 13.6 | 16.5 | 0.111 | 28.6 |
2.5 | 25 | 37 | 29 | 7.41 | 9.01 | 0.102 | 15.6 |
4 | 33 | 48 | 37 | 4.61 | 5.61 | 0.102 | 9.71 |
6 | 42 | 61 | 47 | 3.08 | 3.75 | 0.097 | 6.49 |
4 cores | |||||||
1.5 | 17 | 26 | 21 | 13.6 | 16.5 | 0.111 | 28.6 |
2.5 | 25 | 37 | 29 | 7.41 | 9.01 | 0.102 | 15.6 |
4 | 33 | 48 | 37 | 4.61 | 5.61 | 0.102 | 9.71 |
6 | 42 | 61 | 47 | 3.08 | 3.75 | 0.097 | 6.49 |
7-37 cores | |||||||
1.0 | 14 | 21 | 17 | 18.1 | 25.8 | 0.119 | 51.6 |
1.5 | 17 | 26 | 21 | 13.6 | 16.5 | 0.111 | 33.0 |
2.5 | 25 | 37 | 29 | 7.41 | 9.01 | 0.102 | 18.0 |
Cable Parameter
2 cores
NOM. CONDUCTOR AREA MM2 |
CONDUCTOR NO./ OD | NOM. INSULATION THICKNESS MM |
NOM. SHEATH THICKNESS MM |
NOM. OVERALL DIAMETER MM |
APPROX. MASS KG/KM |
1.5 | 7/0.50 | 0.6 | 0.9 | 8.0 | 95 |
2.5 | 7/0.67 | 0.7 | 1 | 9.6 | 140 |
3 cores
NOM. CONDUCTOR AREA MM2 |
CONDUCTOR NO./ OD | NOM. INSULATION THICKNESS MM |
NOM. SHEATH THICKNESS MM |
NOM. OVERALL DIAMETER MM |
APPROX. MASS KG/KM |
1.5 | 7/0.50 | 0.6 | 0.9 | 8.5 | 120 |
2.5 | 7/0.67 | 0.7 | 1 | 10.1 | 170 |
4 | 7/0.85 | 0.8 | 1.1 | 11.7 | 240 |
6 | 7/1.04 | 1.0 | 1.1 | 13.2 | 300 |
NOM. CONDUCTOR AREA MM2 |
CONDUCTOR NO./ OD | NOM. INSULATION THICKNESS MM |
NOM. SHEATH THICKNESS MM |
NOM. OVERALL DIAMETER MM |
APPROX. MASS KG/KM |
1.5 | 7/0.50 | 0.6 | 0.9 | 9.2 | 130 |
2.5 | 7/0.67 | 0.7 | 1 | 11.4 | 210 |
4 | 7/0.85 | 0.8 | 1.1 | 12.4 | 280 |
6 | 7/1.04 | 1.0 | 1.1 | 13.8 | 330 |
NOM. CONDUCTOR AREA MM2 |
CONDUCTOR NO./ OD | NOM. INSULATION THICKNESS MM |
NOM. SHEATH THICKNESS MM |
NOM. OVERALL DIAMETER MM |
APPROX. MASS KG/KM |
1.0 | 1/1.13 | 0.6 | 0.9 | 10.0 | 150 |
1.5 | 7/0.50 | 0.6 | 0.9 | 11.4 | 195 |
2.5 | 7/0.67 | 0.7 | 1 | 13.3 | 300 |
NOM. CONDUCTOR AREA MM2 |
CONDUCTOR NO./ OD | NOM. INSULATION THICKNESS MM |
NOM. SHEATH THICKNESS MM |
NOM. OVERALL DIAMETER MM |
APPROX. MASS KG/KM |
1.0 | 1/1.13 | 0.6 | 0.9 | 12.9 | 240 |
1.5 | 7/0.50 | 0.6 | 0.9 | 15.0 | 320 |
2.5 | 7/0.67 | 0.7 | 1 | 17.5 | 490 |
NOM. CONDUCTOR AREA MM2 |
CONDUCTOR NO./ OD | NOM. INSULATION THICKNESS MM |
NOM. SHEATH THICKNESS MM |
NOM. OVERALL DIAMETER MM |
APPROX. MASS KG/KM |
1.0 | 1/1.13 | 0.6 | 0.9 | 14.9 | 350 |
1.5 | 7/0.50 | 0.6 | 0.9 | 16.8 | 450 |
2.5 | 7/0.67 | 0.7 | 1 | 21.0 | 760 |
NOM. CONDUCTOR AREA MM2 |
CONDUCTOR NO./ OD | NOM. INSULATION THICKNESS MM |
NOM. SHEATH THICKNESS MM |
NOM. OVERALL DIAMETER MM |
APPROX. MASS KG/KM |
1.0 | 1/1.13 | 0.6 | 0.9 | 17.9 | 480 |
1.5 | 7/0.50 | 0.6 | 0.9 | 21.1 | 670 |
2.5 | 7/0.67 | 0.7 | 1 | 24.8 | 1030 |
NOM. CONDUCTOR AREA MM2 |
CONDUCTOR NO./ OD | NOM. INSULATION THICKNESS MM |
NOM. SHEATH THICKNESS MM |
NOM. OVERALL DIAMETER MM |
APPROX. MASS KG/KM |
1.0 | 1/1.13 | 0.6 | 0.9 | 21.2 | 690 |
1.5 | 7/0.50 | 0.6 | 0.9 | 22.7 | 840 |
2.5 | 7/0.67 | 0.7 | 1 | 27.9 | 1380 |